NFC9180_NFC9180_NFC9180_NFC9180_NFC9180_NFC9180

NFC9180_NFC9180_NFC9180_NFC9180_NFC9180_NFC9180

NFC9180 anti-glare ceiling light brand: Dalang Electric

NFC9180 anti-glare ceiling lamp for the place:

NFC9180 anti-glare dome light is used for fixed lighting in various factories, workshops, power plants and large facilities, venues and other places.

NFC9180 anti-glare ceiling light structure features:

NFC9180 anti-glare dome light efficient, long-life gas discharge lamp as light source, high luminous efficiency and long life;
NFC9180 anti-glare ceiling lamp advanced optical and lighting principle optimized design of transparent parts, soft light, uniform illumination, no glare, effectively avoiding the visual fatigue of the staff;
NFC9180 anti-glare ceiling light. Degree aluminum alloy shell and advanced surface spraying process, anti-corrosion grade WF2, can work reliably in various corrosive environments for a long time;
NFC9180 anti-glare ceiling light structure design, protection grade IP65; ensure that the lamp is waterproof and dustproof;
NFC9180 anti-glare ceiling light ceiling type, wall-mounted and ceiling type and other installation methods, to meet the lighting needs of different work sites.

NFC9180 anti-glare ceiling light use method

NFC9180 anti-glare dome light determines the installation position of the lamp, select the appropriate installation method, and prepare the corresponding length of φ6~8mm three-core cable according to the distance from the lamp to the 220V power contact;
The NFC9180 anti-glare dome light opens the two latches on the lamp holder to open the back cover. Pass one end of the prepared three-core cable through the inlet, connect the live wire (L) to the “L” terminal, and the neutral (N) Connected to the "N" terminal, the ground wire (PE) is connected to the "PE" terminal, and then the cable of the inlet is pressed with the compression nut, the back cover is closed, and the buckle is fastened. Illumination can be achieved by turning on the power at the other end of the core cable.
When replacing the bulb with the NFC9180 anti-glare dome light, open the back cover according to the method of use 2. Rotate the lamp holder to the right and gently pull it out from the lamp cover. Unscrew the old bulb on the lamp holder and replace it with a new one.
NFC9180 anti-glare ceiling light installation:
Ceiling installation: first fix the lifting adapter plate on the luminaire with 4 M8 bolts, and pass the three-core cable through the G3/4 pipe threaded hole, through the side hole and the inlet of the lamp holder side, and connect to On the luminaire, screw the G3/4 pipe thread of the luminaire and the wiring steel pipe with the standard G3/4 pipe thread.
Ceiling installation: According to the installation hole size of the luminaire, the corresponding installation bolt hole is installed at the position where the luminaire is to be installed, and is fixed by M8 bolt.
NFC9180 anti-glare ceiling light with multiple lights in parallel.

NFC9180 anti-glare ceiling light notes:

The NFC9180 anti-glare ceiling light is transported in the carton equipped with the foam and shock absorber.

When the NFC9180 anti-glare ceiling lamp is used, the surface of the lamp has a certain temperature rise, which is a normal phenomenon; the transparent part has a high temperature at the center and must not be touched.

When replacing the bulb with NFC9180 anti-glare dome light, the same type and power bulb should be used; if the bulb type or power is changed, the matching ballast should be replaced accordingly.

NFC9180 glare dome light technical parameters

NFC9180 antiglare dome rated voltage 220VAC 50Hz
NFC9180 antiglare protection IP65 dome housing
NFC9180 glare dome light insulation class I
NFC9180 glare dome light corrosion level WF2
NFC9180 antiglare ceiling Inlet thread G3 / 4
NFC9180 antiglare ceiling drop cable φ6 ~ φ8mm
NFC9180 glare from overhead light than φ8 ~ φ14mm
NFC9180 antiglare ceiling dimensions 226 × 220 × 300mm
NFC9180 antiglare ceiling on the total weight 6Kg
NFC9180 anti-glare ceiling light quality assurance:
This product is in strict accordance with the ISO9001: 2000 international quality management system standards for quality control, to ensure that product quality is higher than the national standard, fully meet the design requirements, the product is guaranteed for 7 years, the light source is guaranteed for one year, within 7 years from the date of purchase, Any failure of the product under normal use is the responsibility of the company for free maintenance.

                                                                           Cabinet Vacuum Suction Unit

ETR has independently developed an integrated vacuum pump unit composed of a water-ring vacuum pump, a gas-water separator, a vacuum solenoid valve, pipe fittings and an electrical control system. It is a simple, safe and reliable device that continuously serves the wards all day long, without occupying the ward space. The negative pressure is sourced from the vacuum pump unit.

Photobank


Cabinet Vacuum Suction Unit

Cabinet Vacuum Suction Unit,Central Suction Station,Negative Pressure Suction Unit,Negative Pressure Suction Station

Hunan Eter Medical Co., Ltd. , https://www.eter-tech.com